WSU Energy Program Logo
Bonneville Power Administration Logo
  • Home
  • About
  • Database
      • Browse
      • Energy Systems
        • Building Envelope
        • Electronics
        • HVAC
        • Irrigation
        • Lighting
        • Motors & Drives
        • Multiple Energy Systems
        • Power Systems
        • Process Loads & Appliances
        • Refrigeration
        • Transportation
        • Water Heating
      • Sector
        • Agricultural
        • Commercial
        • Industrial
        • Residential
        • Utility
  • TAG Portal
      • 2017 Residential Lighting TAG (#14)
      • 2016 Multifamily Building TAG (#13)
      • 2015-1 Commercial HVAC TAG (#11)
      • 2014 Residential Building TAG (#10)
      • 2014 Commercial Building TAG (#9)
      • 2013 Information Technology TAG (#8)
      • 2013 ALCS TAG (#7)
      • 2012 Smart Thermostat TAG (#6)
      • 2012 LED Lighting TAG (#5)
      • 2011 Energy Management TAG (#4)
      • 2010 HVAC TAG (#3)
      • 2009 HVAC TAG (#2)
      • 2009 Lighting TAG (#1)
  • Webinars
    • Webinar Archives
  • Glossary

Loading...

Database

This database currently includes about 300 technologies and is updated regularly. You can scroll through the entire database or you can use the search tool on the right to focus on specific types of technologies or sectors. The search tool defaults to looking for the exact phrase entered in the search box, however a broader search is possible by unchecking the 'Use exact phrase' option.
Refer to our glossary for terms and field definitions used in this database.

 

Current query: "Energy System: HVAC")
Showing 50 items per page
Page: 1 2
80 results
Ongoing Commissioning of Economizers in a Data Center
A maintenance protocol/program to verify performance and make corrections to the air or water side economizers in a data center
TAG Technical Score: 3.28
 
Energy Savings: 10%
Regional Potential: 0.18 MWh/year
ID: 486
 
Natural Ventilation for Mixed-Mode Conditioning
Utilizing natural ventilation (driven by wind and stack effect rather than fans) for nighttime precooling of a building, preferably one with extensive exposed masonry structure in a climate with significant daily temperature swings
TAG Technical Score: 3.18
 
Energy Savings: 20%
Regional Potential: 0.22 MWh/year
ID: 541
 
Direct Server Cabinet Cooling
A special cabinet that encases servers so only the servers are cooled, not the entire server room.
TAG Technical Score: 2.62
 
Energy Savings: 15%
Regional Potential: 0.53 MWh/year
ID: 68
 
Indirect-Direct Stand Alone Evaporative Cooler
A device that employs both indirect and direct evaporative cooling instead of using the vapor-compression/refrigeration cycle. This maximizes evaporative cooling while increasing humidity less than direct evaporative cooling alone.
TAG Technical Score: 2.4
 
Energy Savings: 30%
Regional Potential: 0.37 MWh/year
ID: 23
 
Active Chilled Beam Heating and Cooling
A heating and cooling system that draws room air past hot or cold water heat exchangers and provides conditioned air and necessary ventilation air into the space.
TAG Technical Score:
 
Energy Savings: 20%
Regional Potential: 0.44 MWh/year
ID: 316
 
Add motorized dampers to envelope duct penetrations
Motorized dampers that close automatically when an HVAC fan is turned off, saving energy by reducing infiltration.
TAG Technical Score:
 
Energy Savings: 10%
Regional Potential: 0.64 MWh/year
ID: 426
 
Advanced Design Rooftop Unit
These retrofit units offer improved energy performance over typical existing "commercial" rooftop units by enhancing the performance of individual components and configurations, including fans, coils, filters, dampers, compressors, condensers, controls, and airflow path.
TAG Technical Score:
 
Energy Savings: 60%
Regional Potential: 1.93 MWh/year
ID: 246
 
Advanced Rooftop Unit Controls (ARC) Retrofit
Controllers to retrofit existing rooftop units to optimize performance by providing remote energy monitoring and control as well as variable speed drives, demand-controlled ventilation, and other features.
TAG Technical Score:
 
Energy Savings: 45%
Regional Potential: 2.14 MWh/year
ID: 338
 
Aerosol-Based Duct Sealing for Residential and Commercial Buildings
An aerosol sealant is blown through ducts, plugging leaky ducts from inside the duct system without having to locate or access holes. This technology can be applied to both residential and commercial duct systems.
TAG Technical Score:
 
Energy Savings: 20%
Regional Potential: 1.21 MWh/year
ID: 178
 
Air Flow Management for Data Centers
A collection of techniques and strategies that direct supply air to the servers at a rate needed for server performance while minimizing airflow energy costs.
TAG Technical Score:
 
Energy Savings: 30%
Regional Potential: 1.06 MWh/year
ID: 376
 
Air-Side Economizer for Data Centers
Using up to 100% outside air cooling capability in a data center to provide "free" cooling in an application where outside air would otherwise be provided only to satisfy minimum ventilation requirements.
TAG Technical Score:
 
Energy Savings: 25%
Regional Potential: 0.88 MWh/year
ID: 119
 
Circulating Hot and Chilled Water Pumps with Variable Speed ECPM Motors
Speed-controlled circulating pumps for heating, cooling, and domestic hot water systems using electronically commutated permanent magnet (ECPM) motors.
TAG Technical Score:
 
Energy Savings: 75%
Regional Potential: 0.01 MWh/year
ID: 291
 
Cold Climate Ductless Heat Pump for Residential Application
A variable speed ductless air source heat pump (see ID #300) specifically designed to operate at capacity without supplemental heat down to very low temperatures -- as low as -25F.
TAG Technical Score:
 
Energy Savings: 50%
Regional Potential: 1.60 MWh/year
ID: 199
 
Dedicated Outside Air System (DOAS) for VAV HVAC systems
An outside air ventilation system that is separate from the central air handling and distribution system.
TAG Technical Score:
 
Energy Savings: 10%
 
ID: 248
 
Demand-Controlled Ventilation
Ventilation in commercial buildings controlled by occupancy sensors – usually CO2 monitors – to provide just the required amount of outside air and to avoid over- or under-ventilating a space.
TAG Technical Score:
 
Energy Savings: 10%
Regional Potential: 1.95 MWh/year
ID: 166
 
Demand-Controlled Ventilation for Commercial Kitchens
A system for commercial kitchen exhaust fans that uses smoke and heat sensors to control the exhaust hood airflow and make-up air volume based on cooking activities.
TAG Technical Score:
 
Energy Savings: 57%
Regional Potential: 0.68 MWh/year
ID: 155
 
Desiccant Dehumidifiers for Grocery & Cold Storage
A solid desiccant dehumidifier integrated with the HVAC system that can maintain the humidity level inside a building in the range of 30% to 40%.
TAG Technical Score:
 
Energy Savings: 25%
Regional Potential: 0.26 MWh/year
ID: 313
 
Desiccant-Enhanced Hybrid Evaporative Air Pre-Cooler
Combining the basic indirect evaporative cooler with a desiccant pre-stage allows for evaporative coolers to operate efficiently under higher-humidity conditions than would be normally possible.
TAG Technical Score:
 
Energy Savings: 25%
Regional Potential: 0.20 MWh/year
ID: 49
 
Displacement Ventilation
An air distribution system which supplies low velocity air, typically at floor level. Supplied air rises slowly and is extracted from the ceiling, as opposed to intentionally mixing the air.
TAG Technical Score:
 
Energy Savings: 25%
Regional Potential: 0.24 MWh/year
ID: 18
 
Ducted Variable-Speed Split System Heat Pump
A ducted heat pump leveraging the successful inverter-driven technology found in ductless heat pumps.
TAG Technical Score:
 
Energy Savings: 39%
Regional Potential: 2.60 MWh/year
ID: 332
 
Ductless Mini-Split Heat Pump for Manufactured Homes
Ductless Mini-Split Heat Pumps with Variable Speed Compressors, but this application is designed specifically for use in multifamily residential applications.
TAG Technical Score:
 
Energy Savings: 33%
Regional Potential: 1.11 MWh/year
ID: 301
 
Ductless Mini-Split Heat Pump for Multi-Family Housing
Mini-Split Heat Pumps with Variable Speed Compressors, but this application is designed specifically for use in multi-family homes.
TAG Technical Score:
 
Energy Savings: 41%
Regional Potential: 0.58 MWh/year
ID: 302
 
Ductless Mini-Split Heat Pump for Small Commercial Applications
Ductless mini-split heat pump employing variable refrigerant flow technology without simultaneous heating and cooling, and up to eight zones to be used for small commercial applications. Features of this technology include: 1. A single outdoor unit that provides non-simul...
TAG Technical Score:
 
Energy Savings: 38%
Regional Potential: 0.24 MWh/year
ID: 276
 
Ductless Mini-Split Heat Pumps for Residential Applications
Ductless split systems with non-inverter driven compressors have been available in the U.S. for decades. Within the last few years, the market has begun to shift to using inverter-driven compressors. Non-inverter driven compressors are still used however, typically due t...
TAG Technical Score:
 
Energy Savings: 32%
Regional Potential: 3.04 MWh/year
ID: 300
 
ECPM Motors for Single-phase HVAC Fan Applications
High efficiency electronically commutated permanent magnet (ECPM) motors with inherent variable speed capability that are ideal retrofits for package terminal air conditioners, room air conditioners, unitary condenser fans and blowers, and exhaust fan applications.
TAG Technical Score:
 
Energy Savings: 33%
Regional Potential: 2.44 MWh/year
ID: 101
 
Efficient Laboratory Hoods
A package of lab hood efficiency measures including heat recovery and automatic sash positioning.
TAG Technical Score:
 
Energy Savings: 30%
Regional Potential: 0.42 MWh/year
ID: 185
 
Energy Recovery Ventilator with Heat and Membrane Humidity Exchangers for Commercial Application
An air-to-air heat exchanger that transfers both sensible and latent heat between the exhaust air stream and the fresh air stream using one of a number of membrane-based technologies.
TAG Technical Score:
 
Energy Savings: 65%
Regional Potential: 4.88 MWh/year
ID: 461
 
FANWALL Technology
An air handler made up of an array of smaller fans that replaces a single large fan.
TAG Technical Score:
 
Energy Savings: 5%
Regional Potential: 0.01 MWh/year
ID: 177
 
Heat Recovery Ventilator for Commercial Applications
A heat exchanger to heat or cool incoming fresh or outside air, capturing about 50% to 70% of the sensible heat from the exhaust air that would otherwise be discharged into the atmosphere.
TAG Technical Score:
 
Energy Savings: 30%
Regional Potential: 2.26 MWh/year
ID: 20
 
High-Volume, Low-Speed Fans
A high-volume, low-speed (HVLS) fan up to 24 feet in diameter, capable of displacing many smaller constant speed fans.
TAG Technical Score:
 
Energy Savings: 96%
Regional Potential: 0.02 MWh/year
ID: 620
 
HVAC Embedded Fault Detection and Diagnostics
Smart equipment for commercial and residential HVAC that recognizes when it is failing or has failed, or when environmental conditions have drifted outside its optimum capability range, and can communicate that to personnel.
TAG Technical Score:
 
Energy Savings: 13%
Regional Potential: 0.98 MWh/year
ID: 163
 
Hybrid Direct Expansion With Evaporative Pre-Cooling
Hybrid cooling that couples conventional high-efficiency mechanical cooling with one or more evaporative cooling techniques to minimize compressor electricity demand and consumption.
TAG Technical Score:
 
Energy Savings: 25%
Regional Potential: 0.59 MWh/year
ID: 59
 
Install Ducts in Conditioned Space
Designing buildings with ducts in conditioned space to eliminate the heat loss associated with duct leakage.
TAG Technical Score:
 
Energy Savings: 10%
Regional Potential: 0.05 MWh/year
ID: 154
 
Liquid Submersion Cooling for Data Centers
A method of cooling data center servers by submerging them in dielectric fluid, resulting in reduced energy use, peak demand, and infrastructure requirements compared with air cooling or liquid pipe-to-point cooling.
TAG Technical Score:
 
Energy Savings: 40%
Regional Potential: 1.33 MWh/year
ID: 452
 
Low Pressure Drop Piping System
Piping system designed for low pressure drop saves pump energy.
TAG Technical Score:
 
Energy Savings: 33%
 
ID: 257
 
Low Temp Supply Air to Reduce Volumetric Flow Rate
Lower design supply temperatures for cooling reduce the air volume required to meet loads and reduces fan energy, duct sizing, and potentially first-installed cost.
TAG Technical Score:
 
Energy Savings: 2%
Regional Potential: 0.02 MWh/year
ID: 203
 
Low Temperature Variable Refrigerant Flow (VRF) with or without Simultaneous Heating and Cooling for Large Commercial Applications
Variable refrigerant flow systems for large commercial buildings, similar to ID #126, but designed specifically for climates with frequent low temperatures so that auxiliary heat is not needed, or is needed only at very low temperatures.
TAG Technical Score:
 
Energy Savings: 25%
Regional Potential: 0.33 MWh/year
ID: 311
 
Low-Lift Cooling Technology Option Set
A set of five technologies based on low-lift vapor compression cooling equipment assembled by Pacific Northwest National Laboratory (PNNL) under a single name.
TAG Technical Score:
 
Energy Savings: 42%
Regional Potential: 0.47 MWh/year
ID: 184
 
Mechanical Nighttime Ventilation Cooling
A system that uses an air-side economizer to automatically ventilate a building at night to cool the building's thermal mass and reduce the need for compressor-based cooling the following day.
TAG Technical Score:
 
Energy Savings: 10%
Regional Potential: 0.76 MWh/year
ID: 102
 
Smart Thermostat for Residential HVAC Control
A smart thermostat provides advanced energy management features. Capabilities include occupancy sensing, remote monitoring, data analysis, automation, system optimization, and reporting to optimize control of home space conditioning enabled by advanced technology for sen...
TAG Technical Score:
 
Energy Savings: 12%
Regional Potential: 0.48 MWh/year
ID: 240
 